Connecting ac socket and a transformer

Frequently asked questions regarding powering your pedal.
Locked
User avatar
kin0
Information
Posts: 19
Joined: 25 Sep 2010, 07:41

Post by kin0 »

hay I don't know how to connect this part:

Image

Uploaded with ImageShack.us

any help?

User avatar
Hides-His-Eyes
Tube Twister
Information
Posts: 1940
Joined: 02 Feb 2010, 12:34
Has thanked: 50 times
Been thanked: 51 times

Post by Hides-His-Eyes »

You don't know how to do it physically or don't know where to connect it?
Testing, testing, won too fwee

User avatar
kin0
Information
Posts: 19
Joined: 25 Sep 2010, 07:41

Post by kin0 »

Where to connect (my transformer got 5 wires and the one in the schematic 4, also the same with the socket, mine is different than the schematic).

User avatar
Duckman
Opamp Operator
Information
Posts: 1492
Joined: 20 May 2009, 01:45
Has thanked: 320 times
Been thanked: 134 times

Post by Duckman »

If the 3 cables are your input, you got the option to feed it with 110v or 220v (cable 1 + cable2 = 110v; cable 1 + cable 3 = 220v) If the 3 cables are your output, then you got a central tap, useful when you need a dual voltage configuration, like +9v / -9v and central tap goes to ground.
Any way, verify this before connect any thing (I think I'm missing something)

User avatar
Duckman
Opamp Operator
Information
Posts: 1492
Joined: 20 May 2009, 01:45
Has thanked: 320 times
Been thanked: 134 times

Post by Duckman »


User avatar
kin0
Information
Posts: 19
Joined: 25 Sep 2010, 07:41

Post by kin0 »

Oh I know found that it is written

Black-PRI 220V 50Hz
Red-SEC 6VAC X2 1A
GREY-C.T

so are the black one the input, the red ones once are the output and the grey is ground?

User avatar
mictester
Old Solderhand
Information
Posts: 2924
Joined: 11 Sep 2008, 20:29
my favorite amplifier: Mesa Boogie, Roost Sessionmaster, AC30
Completed builds: Hundreds! Mostly originals, a few clones and lots of modifications.
Location: Somewhat closer to Amsterdam than before!
Has thanked: 32 times
Been thanked: 845 times
Contact:

Post by mictester »

kin0 wrote:Oh I know found that it is written

Black-PRI 220V 50Hz
Red-SEC 6VAC X2 1A
GREY-C.T

so are the black one the input, the red ones once are the output and the grey is ground?
The black ones are the incoming mains supply - correct.

The connection to the output leads depends on the AC voltage you want - your circuit calls for 12V AC, so use the two red wires, and don't connect the grey wire to anything - just insulate the end of it so that it can't touch anything.
"Why is it humming?" "Because it doesn't know the words!"

User avatar
kin0
Information
Posts: 19
Joined: 25 Sep 2010, 07:41

Post by kin0 »

Oh. My transformer is 2x6v. Can I get more than 12v (about 16?)

User avatar
kin0
Information
Posts: 19
Joined: 25 Sep 2010, 07:41

Post by kin0 »

btw can I run a shredmaster with 12v?